MIL-PRF-24793A
4.4.3 Failures. One or more failures shall constitute first article
inspection failure.
4.5 Conformance inspection. Conformance inspection shall consist of the
inspections and tests specified for group A inspection (table III), Group B
inspection (table IV), and Group C inspection (table V), as specified (see
6.2). Requirements for alternate forms of conformance inspection shall be as
identified in the contract (see 6.3.2).
4.5.1 Group A inspection. Group A inspection shall consist of the tests
listed in table III conducted in the order shown.
TABLE III.
Group A inspection.
Inspection
Requirement
Test
Identification and marking
3.5.13
4.6.11
4.5.1.1 Sampling plan. Group A inspections shall be performed on 100
percent of the product supplied under this specification.
4.5.1.2 Failures. One or more failures shall constitute group A inspection
failure of the sample unit.
4.5.1.3 Disposition of sample units. Samples that have failed group A
inspection shall not be shipped or submitted for group B testing.
4.5.2 Group B inspection. Group B inspection shall consist of the tests
listed in table IV conducted in the order shown. Group B inspections shall be
made on sample units that have passed group A inspection.
TABLE IV.
Group B inspection.
Inspection
Requirement
Test
Workmanship
3.5.15
4.6.12
Cure schedule
3.5.4
4.6.3
Hardness
3.5.6
4.6.5
Bond strength
3.5.7
4.6.6
4.5.2.1 Sampling plan. A minimum of three sample units shall be selected
from each lot of material supplied under this specification.
4.5.2.2 Failures.
One or more failures shall constitute group B inspection
failure of the lot.
4.5.2.3 Rejected lots. Requirements regarding the rework of rejected lots
shall be as identified in the contract (see 6.8.1).
4.5.2.4 Disposition of sample units. Samples that have failed group B
inspection shall not be shipped or submitted for group C testing.